视力增强型双焦点人工晶状体(AM4UH)、双焦点人工晶状体和单焦点人工晶状体术后视力及视觉质量的比较

 

Authors Xu Z, Ma X, Gao J, Liu F, Han D

Received 27 August 2025

Accepted for publication 21 January 2026

Published 3 February 2026 Volume 2026:19 563632

DOI https://doi.org/10.2147/IJGM.S563632

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 3

Editor who approved publication: Dr Brian C. Gilger

Ziwei Xu, Xinli Ma, Jiayue Gao, Fa Liu, Dan Han

Department of Ophthalmology, Harbin 242 Hospital, Harbin City, People’s Republic of China

Correspondence: Dan Han, Email 18633045725@163.com

Objective: To compare visual acuity and visual quality after implantation of Vision Enhancing bifocal intraocular lens (IOL), bifocal IOL or monofocal IOL in patients with age-related cataract.
Methods: Retrospective study. Group A was implanted with Vision Enhancing bifocal (bifocal combined extended depth of focus (EDOF)) IOL (Eyebright Medical Technology (Beijing) Co. Ltd. China: AM4UH, 21 eyes), group B was implanted with bifocal IOL (Johnson & Johnson, USA: ZMB00, 21 eyes), and group C was implanted with monofocal IOL (Eyebright Medical Technology (Beijing) Co. Ltd. China: A1UL22, 21 eyes). At 3 months postoperatively, uncorrected distance visual acuity (UDVA) was compared among 3 groups, while uncorrected near visual acuity (UNVA) and uncorrected intermediate visual acuity (UIVA), defocus curves, and visual quality questionnaire results were compared between Group A and B.
Results: There was no statistically significant difference in UDVA among three groups postoperatively (P > 0.05); in terms of UIVA and UNVA, group A was better than group B (P < 0.05); the defocus curves showed that group A was close to bimodal but tended to be flat, while group B was bimodal; groups A and B became spectacle-independent postoperatively, and 40% of patients in group B reported the halo phenomenon, especially when driving at night.
Conclusion: Vision Enhancing bifocal IOL (AM4UH) exhibited a better UIVA and UNVA, indicating a continuous visual range. And patients implanted with AM4UH achieved postoperative spectacle independence, with less visual disturbance.

Keywords: age-related cataract, intraocular lens, extended depth of field